Fleck Model: 9000

Twin Econominder Demand Regeneration Control

Fleck 9000
Download Service Manual

Email customercare@fleckvalves.com to Order Now!

Features

  • Fully adjustable 5-cycle control delivers controlled upflow backwash, downflow brining, slow rinse, rapid rinse, timed brine refill, and downflow service.
  • Perfect for light commercial/heavy residential systems that require twin tank conditioning capabilities.
  • Continuous flow rate of 21 gpm.
  • All cycles easily adjustable. Program just what is needed with “all cycle” variable time control.
  • Backwash capacity handles tanks up to 16″.
  • Choice of ¾” or 1″ meter satisfies wide range of operational needs.

Options

  • Bypass valve (Noryl or lead free brass)
  • Hot water (150° F max, 1″ only)
  • 3/4″ inlet/outlet Electronic timer
  • Window cover
  • Nickel plating

Valve Specifications

Valve MaterialLead Free Brass
Inlet/Outlet3/4" or 1" NPT (Female)

Flow rates (50 PSI Inlet) - Valve Alone

Flow Rate (50 PSI inlet)1" - 3/4"
Continuos (15PSI Drop)21gpm - 18
Peak (25 PSI Drop)28 gpm - 24
CV**5.1 - 4.8
Max.Backwash (25 PSI Drop)8.5 gpm - 8.5

Regeneration

Downflow/UpflowDownflow
AdjustableYes
Time Available164 minutes or 82 minutes

Meter Information

Meter Accuracy Range (1"):1": 7 - 300 gpm ± 5%
Meter Capacity Range (1"):Std: 3,750 - 63,750 gal
Ext:18,750 - 318,750 gal
Meter Accuracy Range (3/4"):0.25 - 15gpm ± 5%
Meter Capacity Range (3/4"):Standard: 125 - 2,125 gals.
Extended: 625 - 10,625 gals.

Dimensions

Distributor Pilot1" (1.050) O.D.
Drain Line 1/2" NPT
Brine Line3/8"
Mounting Base 2-12/"-8 NPSM)
Height from top of tank 6-1/2"

Tank Application

Water Softener6"-16" diameter

Additional Information

Electrical Rating24v, 110v, 220v-50 Hz, 60 Hz
PressureHydrostatic: 300 psi
Working: 20 - 125 psi
Temperature34° - 110° F