| This web site is designed to be an engineering
tool as well as a resource for locating companies that service,
install, and sell Fleck Controls and Fleck Valve parts and
equipment. Model numbers as well as specifications will vary
slightly from one supplier to another. Not all items pictured on
this web site are available at all locations listed nor are all
items manufactured by Fleck Controls. Contact the individual
supplier in your area for their current information. |


| |
Model 2750 -
1" water conditioning control |
|

2750/1600/T
Time clock
$298.00 |
- Suitable for large
residential/light commercial applications
- Excellent flow rates -
up to 26 gpm
- Fully adjustable
5-cycle control delivers controlled upflow backwash, downflow
brining and slow rinse, rapid rinse, timed brine refill, and
downflow service
- Backwash capacity
handles tanks up to 24" diameter
- Choice of 7/12 day
clock, manual or meter initiated regeneration
- Valve body is solid
lead free brass
- Hard water bypass
feature is standard
- Time tested,
hydraulically balanced piston, seal, and spacer concept to pilot
service flow and regeneration
|
Options
Backwash filter
Hot water (time clock 180°F
Meter 150°F)
Meter initiated regeneration
Manual operation
Service valve operator
No hard water bypass piston (Downflow)
Upflow models available with pressure regulated injector (Specify 1600
or 1700 brine system)
Electronic timer
Enviromental cover
Nickle plating.
|
|
Valve
Specifications
|
| Valve
Material |
Lead
free brass |
|
Inlet/Outlet |
1"
NPT Male |
|
Cycles* |
{5}
|
|
Flow
rates (50 PSI Inlet) - Valve Alone
|
|
Continuous (15 PSI Drop) |
26
GPM |
| Peak
(25 PSI Drop) |
33
GPM |
| CV** |
6.8
|
|
Max.Backwash (25 PSI Drop) |
25
GPM |
|
Regeneration
|
|
Downflow/Upflow |
Both
|
|
Adjustable |
YES
|
| Time
Available |
164
minutes |
|
Meter
Information
|
| Meter
Accuracy Range |
.0.7
- 40 gpm +/- 5% |
| Meter
Capacity Range |
Standard: 310 - 5,270 gals.
Extended: 1,550 - 26,350 gals. |
|
Dimensions
|
|
Distributor Pilot |
1"
(1.050) pipe O.D. |
| Drain
Line |
3/4"
N{T (Male) |
|
Brine Line |
3/8" (1/2" available)
|
|
Mounting Base |
2-1/2"-8 NPSM |
|
Height from top of tank |
6-1/2"
|
| Tank Application - can regenerate/backwash the following |
|
Water
Softener |
10"-24" diameter |
|
Iron Filter
|
10"-21" diameter
|
|
Sediment Filter
|
10"-21" diameter
|
|
Carbon Filter
|
10"-21" diameter
|
|
Neutralizing
Filter
|
10"-21" diameter
|
|
Additional Information
|
|
Electrical Rating |
24V,110V,220V-50Hz, 60Hz |
|
Pressure |
Hydrostatic: 300 PSI
Working: 20-125 PSI |
|
Temperature |
34° -
110°F |
**Cv-Flow rate of valve alone at 1 psi pressure drop
|